  • Code SP9061

    提示

    SEMI-FULL ERROR EXCESS

    说明

    The error between the semi-closed and full-closed sides when the dual position feedback function is used is too large.

    解决方法

    Check parameter settings.
  • Code SP9059

    提示

    PS INTERNAL FAN FAILURE

    说明

    The internal cooling fan for the Power Supply (PS) stopped. (Power Supply alarm indication: 02)

    解决方法

    Replace the Power Supply (PS).
  • Code SP9058

    提示

    PS OVERLOAD

    说明

    The temperature of the radiator of the Power Supply (PS) has increased abnormally. (Power Supply (PS) alarm indication: 03)

    解决方法

    (1) Check the Power Supply(PS) cooling status. (2) Replace the Power Supply (PS).
  • Code SP9057

    提示

    PS EXCESS-REGENE RATION2

    说明

    An overload was detected in the regenerative resistance. (Power Supply alarm indication: 16) Thermostat operation or short-time overload was detected. The regenerative resistor was disconnected, or an abnormal resistance was detected.

    解决方法

    (1) Decrease the acceleration/deceleration duty. (2) Check the cooling condition (peripheral temperature). (3) If the cooling fan stops, replace the resistor. (4) If the resistance is abnormal, replace the resistor.
  • Code SP9056

    提示

    COOLING FAN FAILURE

    说明

    The internal cooling fan stopped.

    解决方法

    Replace the internal cooling fan.
  • Code SP9055

    提示

    ILLEGAL POWER LINE

    说明

    The power line state signal of the magnetic contactor for spindle switching/speed range switching is abnormal.

    解决方法

    (1) Replace the magnetic contactor. (2) Check and correct the sequence.
  • Code SP9054

    提示

    OVERCURRENT

    说明

    An overload current was detected.

    解决方法

    Review the load state.
  • Code SP9053

    提示

    ITP FAULT 2

    说明

    An abnormality is detected in the interface between the CNC and spindle amplifier (the ITP signal stopped).

    解决方法

    (1) Replace the Spindle Amplifier (SP) control printed circuit board. (2) Replace the main board or additional spindle board in the CNC.
  • Code SP9052

    提示

    ITP FAULT 1

    说明

    An abnormality is detected in the interface between the CNC and spindle amplifier (the ITP signal stopped).

    解决方法